EMS for solar, wind and battery plants
Run every plant from one screen.
Windrise EMS optimizes your energy and picks the best market for every hour: ancillary services, day-ahead or intraday, including cross-border export. It balances to your notified energy and keeps every plant inside its grid limits. Already controlling 100 MW across Europe.
01 The gap
Other EMS software waits for a plan. Windrise EMS builds it.
In most EMS software the plan is still made by hand and keyed in. In Windrise EMS the optimizer completes the schedule automatically, and the market workflow and the infrastructure come with it.
The plan: by hand elsewhere, automatic here
In other EMS software, schedules are worked out in spreadsheets and keyed in hour by hour. In Windrise EMS the optimizer completes the schedule automatically, from the forecast, prices, state of charge and imbalance cost.
The market: separate elsewhere, built in here
Elsewhere, forecast, day-ahead notification and balancing sit in different tools, and a missed hour is paid for in imbalance. Here they are one workflow.
The infrastructure: yours elsewhere, ours here
Elsewhere, servers, VPNs, firewalls, monitoring and alert delivery become another project for the plant owner. Here they are part of the service.
02 The platform
Built for the people who run plants.
Real screens from the platform, with customer names removed.
Tap a screen to enlarge
Every plant at a glance
Live PV power, battery state of charge, plant status and limit source, with yesterday, today, month and year production against forecast.
- Export and import limits, BESS and PV capacity
- EMS state and active limit source
- Date navigation on every chart


Grid and devices, live
Line voltages, current, frequency and power factor at the connection point, the grid meter's total export and import, and the state of every device on site.
- Battery, inverter, meter, power analyzer and logger status
- Grid meter totals for export and import


The whole fleet on one map
Every plant on the map with what it produces and delivers right now: active power, power delivered to the grid, plants online, PV capacity and battery capacity.
- Map and list views
- Filter to plants with storage


Manual or automatic, executed on the hour
Set charge, discharge, grid charging or balancing for each hour yourself, or let the optimizer fill the day automatically. Battery state of charge, the balancing hour and the EMS status sit above the schedule.
- Per-plant, per-hour mode and value
- CSV import for schedules built elsewhere
- Saved dates you can reload


Every plant's schedule side by side
A read-only view of the hourly schedule of every plant: balancing, charging, discharge and grid charging, with the current hour marked.
- All plants or storage only
- Grouped by balancing group


Forecast, notify and optimize for the group
One workspace per balancing group: the forecast for every plant and hour, the total, and the volume you notify. The optimizer proposes the plan for the next day from the same screen.
- Send the notification from the grid
- Export to .xlsx
- Pin a value by hand and keep the live forecast for the rest


Income and market in one view
Notified energy, positive and negative imbalance and profit for every hour, next to the day-ahead price curve of the market the plant sells on.
- Day, month and year views
- Imbalance in both directions, hour by hour
- CSV export


The dispatcher view
One table for the whole fleet: online status, PCS power and state, SoC, export, frequency, line voltages and current, with filters and one-click access to control.
- Configurable columns and filters
- Direct jump into plant control


Direct control, with guard rails
Power conversion on and off, active and reactive power setpoints, control modes and plant limits, restricted by role and recorded in the audit log.
- Viewer, trader and admin roles per plant
- Relays and plant limit control
- Live refresh every 60 seconds


03 Packages
Four packages. Each one builds on the last.
Pick the package that matches your plant. Every package includes everything in the one below it, so a plant can move up as it grows.
- 01
BASIC
PV or wind, no storage
Includes- SCADA monitoring of the plant
- Production planning in the EMS Scheduler, based on forecast
- Limiting source power to cut positive imbalance
- Central EMS controller on site
- 02
MEDIUM
One PCS and one storage system under 10 MWh
BASIC, plus- Storage control, manual and scheduled
- Balancing to the notified energy: positive and negative imbalance
- Load shifting for price arbitrage
- PCS functions: frequency, voltage and reactive power
- 03
ADVANCED
Stations from 2.5 MW / 5 MWh up to 50 MW
MEDIUM, plus- Ancillary services on the balancing market (PEE)
- Grid charging
- Participation in a balancing VPP
- Stations with more than one PCS
- 04
ADVANCED+
ADVANCED with the trader system
ADVANCED, plus- Day-ahead optimizer: automatic schedule with profit optimization
- ML and AI for prediction
- API for the trader's platform
| Function | ||||
|---|---|---|---|---|
| From BASIC | ||||
| Automation and EMS cabinet – central EMS controller | Available | Available | Available | Available |
| SCADA Windrise EMS | Available | Available | Available | Available |
| Production planning – EMS Scheduler based on forecast | Available | Available | Available | Available |
| Limiting source power – reduction of positive imbalance against the plan | Available | Available | Available | Available |
| Integration with the energy exchange | Option | Available | Available | Available |
| From MEDIUM | ||||
| Manual storage control (charge / discharge) | Not available | Available | Available | Available |
| Balancing to the notified energy – positive and negative imbalance | Not available | Available | Available | Available |
| Peak shaving | Not available | Option | Option | Option |
| Load shifting – price arbitrage | Not available | Available | Available | Available |
| Increasing self-consumption / "zero" export | Not available | Option | Option | Option |
| Phase voltage balancingPCS function. The range depends on the converter. | Not available | Available | Available | Available |
| Voltage regulationPCS function. The range depends on the converter. | Not available | Available | Available | Available |
| Frequency regulationPCS function. The range depends on the converter. | Not available | Available | Available | Available |
| Reactive power compensation (power factor correction)PCS function. The range depends on the converter. | Not available | Available | Available | Available |
| Shared grid connection – export limit control | Not available | Available | Available | Available |
| Operation in off-grid modeAccording to investor requirements. | Not available | Option | Option | Option |
| From ADVANCEDStations from 2.5 MW / 5 MWh up to 50 MW | ||||
| Consumption optimization – load control (if present) | Not available | Not available | Available | Available |
| Stations with more than one PCS (> 1 PCS) | Not available | Not available | Available | Available |
| Grid charging | Not available | Not available | Available | Available |
| Ancillary services on the balancing market (PEE) | Not available | Not available | Available | Available |
| Participation in a balancing VPP (PEE) | Not available | Not available | Available | Available |
| ADVANCED+ onlyThe trader system | ||||
| Day-ahead optimizer – automatic schedule creation with profit optimization | Not available | Not available | Not available | Available |
| ML and AI for prediction | Not available | Not available | Not available | Available |
| API for integration with the trader's platform | Not available | Not available | Not available | Available |
04 Capabilities
What the platform does, and where each feature stands.
Every capability carries a status so you know exactly what runs today and what we switch on for your project.
Planning & optimization5
Day-ahead optimizer
LiveMILP optimization across a balancing group: state of charge, efficiency, power, ramp, grid limits and imbalance cost. Part of ADVANCED+.
EMS Scheduler
LivePlan every hour from the production forecast: set charge, discharge and balancing by hand, or let the optimizer fill the schedule. Executed on the hour.
Limiting source power
LiveOnce the planned energy for the hour is delivered, generation is limited so the plant does not create positive imbalance.
Balancing to the notified energy
LiveEvery minute the battery is steered to deliver the energy notified for the hour, covering positive and negative imbalance.
15-minute schedules
In platformFiner resolution to match 15-minute market products. Activated per project.
Markets & trading8
Trading view and notification
LivePer-group forecast grid, lock and send the day-ahead notification to Energocom.
PV forecast
LiveForecast integration with revisions and manual edits for the trader.
Day-ahead market prices
LivePrices for Romania and Moldova alongside your plan and incomes.
Intraday trading
In platformAdjust positions after the day-ahead close. Activated per project.
Ancillary services (PEE)
In platformAncillary services on the balancing market for stations from 2.5 MW / 5 MWh: the battery discharges for upward regulation and charges for downward regulation. Part of ADVANCED, activated per project.
Balancing VPP (PEE)
In platformReal-time balancing across a group of plants as one virtual power plant. Part of ADVANCED, activated per project.
Best-market selection
In platformCompares ancillary, day-ahead and intraday for every hour and picks the best price, with income shown side by side. Activated per project.
Cross-border export
In platformExport plant energy across borders to the market that pays the most. Activated per project.
Control & safety6
Grid operator limit priority
LiveThe operator's power limit always wins. The EMS reads it and logs every time it clamps your output.
Safety layer
LiveSoC limits and monitor, direction-reversal guard, emergency stop, and fail-closed on stale telemetry.
Manual control and roles
LiveSetpoints, relays and plant limit from the dashboard, with viewer, trader and admin roles per plant.
Grid charging
LiveCharge the battery from the grid in the hours you choose, with a switch per plant. Part of ADVANCED.
Shared grid connection
LiveExport limit control for several sources behind one connection: the combined output stays inside the connection limit.
PCS functions
LiveFrequency regulation, voltage regulation, phase voltage balancing and reactive power compensation are done by the PCS wherever a battery is attached. The range depends on the converter.
Options & advanced modes7
Load shifting, price arbitrage
LiveCharge in cheap hours and discharge in expensive ones through the schedule.
Stations with more than one PCS
In platformLarger stations, up to 50 MW, with several PCS units. Part of ADVANCED, activated per project.
Price-driven PV curtailment
In platformCurtail only when it pays, not just to avoid imbalance. Activated per project.
Consumption optimization, load control
In platformEV charging, electrolysers and heat pumps managed with the same plan, where controllable loads are present. Part of ADVANCED.
Peak shaving
On requestCut demand peaks with the battery. An option from MEDIUM up.
Self-consumption and zero export
On requestKeep generation on site and maximize own use. An option from MEDIUM up.
Off-grid operation
On requestAccording to investor requirements. An option from MEDIUM up.
Monitoring & alerts4
Fleet dispatcher
LiveStatus, PCS state, SoC, export, frequency, voltages and current for every plant in one table.
Real-time Telegram alerts
LiveInstant notifications with configurable thresholds and offline detection for plants, devices and links.
Audit log and historian
LiveEvery command recorded. One-minute historian for all measurements.
Email and SMS alerts
On requestReal-time Telegram alerts are standard. Email and SMS delivery can be added for your project.
Connectivity & security5
Industrial protocols
LiveModbus, IEC 61850, IEC 60870-5-104 and OPC UA toward batteries, inverters, meters and the grid operator.
DNP3
On requestAdditional protocol interface for your SCADA or utility, added to your project on request.
REST API
LiveOpenAPI-documented interfaces for a trader's platform and for your own tools and reports. The trader integration is part of ADVANCED+.
Cloud or on-premises
LiveHosted by us or deployed on your premises. One VPN tunnel per plant, plants isolated from each other, TLS at the edge.
Cybersecurity standards
Coming soonDesigned with reference to ISO/IEC 27001, IEC 62443 and the EU NIS 2 Directive.
05 How it works
Fast control on site. Intelligence in the cloud.
A PLC at each plant handles the fast loop. The EMS plans, supervises and talks to the market.
Plant
PV inverters, battery PCS and meters, reached over Modbus and IEC 61850 through a high-quality industrial PLC on site (WAGO, Phoenix Contact, Siemens).
On siteSecure link
One dedicated VPN tunnel per plant. Telemetry and commands flow over OPC UA, with a 5-second heartbeat.
Per plantWindrise EMS
Forecast, optimize, schedule, balance, monitor and alert. Cloud-hosted by us, or deployed on premises.
Cloud · On-premGrid and market
Grid-operator limits over IEC 60870-5-104 at the PLC. Day-ahead notification to Energocom.
Europe06 Compared
The layer above the controller.
| Question | Typical stand-alone controller | Windrise EMS |
|---|---|---|
| Who builds the schedule? | You or your trader, then push setpoints in. | Your choice: set it manually, or let the EMS optimizer build the day-ahead plan automatically. |
| Which market? | You compare and choose by hand. | Compares ancillary, day-ahead and intraday and picks the best price, with cross-border export where the plant is connected. |
| Market workflow | Outside the product. | Forecast, notification and minute-by-minute balancing in one tool. |
| Hosting and network | Customer provides server, VPN and firewall. | Cloud-hosted by us or deployed on premises, with a VPN tunnel per plant included. |
| Several plants | One plant, one server. | Fleet view and group optimization by design. |
| Local experience | Documentation and support abroad. | 100 MW under control in Europe, interface in EN, RO and RU. |
| Alerts | Customer supplies mail infrastructure. | Real-time Telegram alerts delivered by us. |
Windrise EMS is a supervisory EMS with a trading layer. Fast grid-code control stays in the on-site PLC. Where a project needs a dedicated plant controller, we work alongside it.
07 Who it is for
Three ways teams use it.
Plant owners and IPPs
Maximize revenue from solar and storage without building a control room. See every plant, plan and alarm in one place.
Traders and aggregators
Forecast, notify and balance a group of plants from the Trading View. ADVANCED+ adds the day-ahead optimizer and an API that connects the EMS to your own platform.
EPCs and integrators
Deliver projects with a ready EMS and a proven grid-approval route instead of building your own.
08 Security
Isolated by design.
Each plant has its own VPN tunnel and cannot see the others. Internal services are not exposed to the internet, traffic is encrypted at the edge, and every command is written to an audit trail.
Network
Per-plant VPN, isolated plants, TLS at the edge, separate dev, staging and production.
Access
Role-based access per plant and a full command audit trail.
Operation
Fail-closed on stale telemetry and a guard against direction reversal on the battery.
Coming soon Cybersecurity standards. The EMS is designed with reference to ISO/IEC 27001 (information security management), IEC 62443 (security of industrial automation and control systems) and the EU NIS 2 Directive.
09 Who is behind it
Built by a group that builds plants.
Windrise Energy is part of the Windrise Plus group in Moldova, which designs and builds solar and battery plants and takes them through to grid commissioning.
PV and BESS, end to end
Engineering, procurement and construction of photovoltaic and battery storage plants, including grid commissioning and an electrotechnical laboratory.
ISO 9001:2015
Quality management standard listed by the group on its website.
Energy supply partner
Supply through Trade Energo Plus, licensed by ANRE for electricity and natural gas in Moldova.
Visit wind-rise.com to see the group's plants and services.
10 FAQ
Straight answers.
Is Windrise EMS certified for grid connection?
Yes. Windrise EMS has passed grid-connection approval with a European grid operator, and the plants using it operate and sell energy to the grid. Fast control is handled by a high-quality industrial PLC on site.
Which hardware does it work with?
Plant devices are reached through a high-quality industrial PLC on site (WAGO, Phoenix Contact or Siemens), so inverters, battery systems and meters are integrated through that PLC. Tell us your equipment and we will confirm the setup.
Where is it hosted?
In the cloud, hosted and operated by us, or on premises, depending on your requirements.
Which package fits my plant?
BASIC is for PV or wind plants without storage. MEDIUM adds one PCS and one storage system under 10 MWh. ADVANCED is for stations from 2.5 MW / 5 MWh up to 50 MW and adds the balancing market. ADVANCED+ adds the trader system. Each package includes everything in the one below it.
Do you cover Europe?
Yes. The platform includes market data and forecasting for European day-ahead markets, and the interface is available in English, Romanian and Russian.
What does "In platform" mean?
The capability exists in the software and is switched on for your plant during commissioning. "Live" features already run at operating plants.
Can the EMS provide ancillary services?
Yes, in the ADVANCED package, for stations from 2.5 MW / 5 MWh up to 50 MW: ancillary services on the balancing market (PEE), grid charging and participation in a balancing VPP. They are activated for your project at commissioning. Contact us for the markets available to your plant.
Is it ISO 27001 and NIS 2 ready?
Coming soon. Windrise EMS is designed with reference to ISO/IEC 27001, IEC 62443 and the EU NIS 2 Directive.
Which protocols are supported?
Modbus, IEC 61850, IEC 60870-5-104 and OPC UA are supported. DNP3 can be added on request.
See it on your plant.
Tell us about your site and we will show the platform with a plan for your connection and market.
Or write to contact@windrise.energy